DDA106-XLR

DDA106_XLR_REAR.png

INPUT

CONNECTORS
XLR female or BNC; paralleled input connectors for loop-thru expansion

LEVEL
XLR 0.2Vp-p minimum; BNC 0.1Vp-p minimum

IMPEDANCE
Transformer isolated, balanced and floating, XLR 110 ohms, BNC 75 ohms; terminating resistors may be switched in or out via front panel control

SAMPLING FREQUENCY
27 to 192kHz

CABLE LENGTH
> 1000 feet (300 meters) of 110 ohm cable with equalizer; 75 ohm coax allows longer runs

EQUALIZER
Automatic EQ for long lines via front panel push button

CLOCK
Regenerated from input signal with dual mode PLL or non-reclocked to preserve Surround coding, switchable

OUTPUTS

CONNECTORS
XLR Male or BNC Female, 6 or 12 depending on model

LEVEL 
XLR 4Vp-p loaded; BNC 2Vp-p loaded

IMPEDANCE
XLR 110 ohms, balanced and transformer isolated; BNC 75 ohms, unbalanced

OUTPUT JITTER
< 300 picoseconds peak to peak. 

PROPAGATION DELAY
< 25 nanoseconds

INDICATORS

INPUT FAULT 
(DDA-212 Only) Input 1, Input 2; identifies input with error condition

INPUT TERMINATION
On, Off

INPUT SAMPLE RATE
32, 44.1, 48, 88.2, 96, 176.4 and 192 kHz

INPUT WORD LENGTH 
16, 18, 20 and 24 bits

INPUT DIGITAL ERRORS
Bi-Phase/Parity, Validity, Non-Linear PCM, DTS-CD Signal

RE-CLOCKING 
Off, On

MODE
Pro, Consumer

INPUT CABLE EQ
Locked, Enabled

INPUT SELECT
DDA-106: 1, 2; 

DDA-212: 1, Bridge, 2

POWER 
Internal Supply, 115/230VAC (selectable via internal jumper) ±10%, 50/60Hz, 10VA, IEC320 3 pin connector

SHIPPING SIZE
20.5” W x 4“H x 11”D; 7.2 lbs. 

WARRANTY 